Earn PRO Points on every order

Redeem points for store credit on your next order

100 PTS = $1

TRUSTED BY CONSTRUCTORS

R-Value 5.66

DIY-Friendly Kit

Spray Foam Insulation Can Bulk Pallet

TRUSTED BY CONTRACTORS

Ideal for Contractors

R-Value 5.66

Spray Foam Insulation Can Bulk Pallet

$1,249.99
You're Saving $0 OFF

IXIRPRO Spray Foam Insulation Can Bulk Pallet is a high-quantity supply format for contractors, distributors and multi-area projects using compatible gun-grade polyurethane foam. The pallet quantity does not change the application limits of each can: coverage, curing and finished performance still depend on thickness, temperature, substrate, technique and waste.

Quick answer: Choose 108 or 216 cans only after calculating target area at the required thickness, adding waste and confirming safe storage capacity. Every applicator must follow the current label, Safety Data Sheet, PPE, ventilation and building requirements.

Show moreShow less

What This Spray Foam Can Is Designed For

The can dispenses expanding polyurethane foam through a compatible applicator. The gun helps control output, but the selected foam, assembly design and local requirements determine whether the product is suitable for a rim joist, wall cavity, roofline, metal surface, window or service penetration. Do not use it as structural reinforcement, a universal waterproofing system or a firestop unless the current product documentation specifically approves that use.

Bulk Quantity, Coverage and Thickness Planning

The current product page presents pack estimates based on a stated coverage per can. Treat these numbers as planning estimates rather than guaranteed finished area. Actual yield can decrease because of thicker passes, overspray, irregular cavities, cold material, poor substrate preparation, start-and-stop losses or application waste.

Planning variable Why it changes yield
Applied thickness Doubling the thickness approximately halves the area available from the same volume before waste.
Surface profile Rough, open or irregular cavities require more material than a flat test surface.
Temperature and humidity They affect expansion, cell formation, curing and the consistency of the spray pattern.
Technique and waste Overspray, pauses, blocked tips and unplanned trimming reduce usable yield.

Use the IXIRPRO spray foam calculator as an initial estimate, then include a reasonable waste allowance and verify the current label's coverage basis before ordering.

Substrate and Project Suitability

  • Remove dust, oil, loose paint, frost and standing moisture before application.
  • Protect finished surfaces and test adhesion on an inconspicuous area.
  • Check clearances around heat sources, flues, chimneys, recessed fixtures and electrical equipment.
  • Do not spray over active leaks, wet or deteriorated materials without correcting the underlying cause.
  • For roof decks, unvented attics, occupied spaces and code-regulated assemblies, confirm the design with a qualified professional or authority having jurisdiction.

Application Setup

  1. Read the label and Safety Data Sheet and isolate the work area from occupants, children and pets.
  2. Condition the can and work area only within the temperature range specified by the manufacturer.
  3. Attach a compatible IXIRPRO Spray Foam Gun without forcing the valve or thread.
  4. Wear the specified eye, skin, clothing and respiratory protection and provide mechanical ventilation where required.
  5. Test the spray pattern on scrap material, then apply controlled passes without exceeding the recommended lift thickness.
  6. Allow each pass and the completed application to cure according to the current instructions before trimming, coating or re-occupying the area.

R-Value and Moisture Claims

R-value is a tested property of a particular foam at a specified thickness and condition; it should not be inferred only from the words “closed cell.” Use the value and thickness stated on the current technical documentation when designing the assembly. Likewise, low water absorption or vapor resistance does not mean every application is a complete waterproofing or vapor-control system. Joints, penetrations, substrate moisture and required membranes still matter.

Cleaning and Storage

Uncured foam is easier to remove than cured foam. Keep a compatible spray foam gun cleaner available before opening the can and follow the applicator instructions. Do not improvise solvents or force cured foam through the gun. Store the pressurized can upright, away from heat, flame and direct sunlight, within the temperature limits on the label.

Safety and Re-Occupancy

Polyurethane foam aerosols can be extremely flammable and may expose the user to irritating or sensitizing chemicals during application and curing. Keep ignition sources away, ventilate the area and follow the label and Safety Data Sheet for PPE, cure time and re-entry. Do not assume a generic 24-hour statement applies to every temperature, ventilation rate or project.

Frequently Asked Questions

How much area does one can cover?

Use the product page's current estimate only at its stated thickness and conditions. Actual coverage varies with thickness, substrate, temperature, technique and waste, so calculate the project volume and add a realistic allowance.

Can I use the can without a foam gun?

This product is presented as a gun-grade can. Confirm the valve and applicator requirements on the label; do not force an incompatible straw, adapter or gun onto the container.

Is the foam suitable around windows and doors?

Only if the label permits that application and the expansion pressure is appropriate for the frame. Excess expansion can distort components, so use a product and method designed for the assembly.

Can it be used as a firestop?

Not unless the exact product and complete assembly have the required firestop approval. Ordinary expanding foam must not be substituted for a tested fire-blocking or firestop system.

When can cured foam be cut or painted?

Follow the current label's tack-free, trim and full-cure times. Temperature, humidity and bead thickness can change the schedule; do not coat uncured foam.

Build a Compatible System

Pair the can with a compatible foam gun, plan cleanup before application and compare the complete IXIRPRO Spray Foam Insulation Kit when accessories and project quantities need to be selected together. Verify the latest product documentation before purchase.

Pack

Estimated Delivery: 4-6 Business Days

365-Day Guarantee

Free Shipping

American Owned

🧱 Spray Foam Can Calculator

Ixirpro Spray Foam Insulation Calculator

Easily estimate how many spray foam insulation cans you'll need for your project. One can covers up to 20 sq.ft. at 1-inch thickness and delivers a strong R-value of 5.66.

Length (ft):
Height (ft):
Thickness (inch):
Area (sq.ft.):
1
Cans Needed:
1 can(s)
R-Value:
5.66

Product Specs.

Type: Closed-cell polyurethane expanding foam sealant

Application: Insulation and sealing for walls, ceilings, doors, windows, and gaps

Main Components:

  • Diphenylmethane-4,4'-diisocyanate (5–25%)
  • Propane, Butane, Dimethyl Ether (propellants)

Physical Properties:

  • Appearance: Light yellow aerosol foam
  • Density: 22 ± 3 kg/m³
  • Flash Point: 0 °C (pressurized)
  • Solubility: Reacts with water (insoluble)
  • Odor: Characteristic

Safety Information:

  • Classification: Extremely flammable aerosol
  • Hazards: May cause skin, eye, and respiratory irritation; prolonged exposure may affect organs.
  • Storage: Keep in a cool, well-ventilated place; do not expose to temperatures above 50 °C.
  • Precautions: Use gloves, goggles, and adequate ventilation during application.

Environmental Note:

Not biodegradable; avoid release into soil or water. Dispose of containers safely in accordance with local regulations.

Technical Resources & Product Manuals

Insulate Like a Pro in 6 Simple Steps 

Advanced Insulation Solutions

Made Simple

Premium spray foam solutions crafted for contractors, builders, and dedicated DIYers. Ensure dependable coverage, airtight seals, and consistent insulation results without the need for complex tools or costly professional services.

Your Questions, Our Answers:

Which types of projects are bulk spray foam pallets intended for?

Bulk pallets are perfect for contractors working on large-scale insulation tasks across multiple rooms or properties, including garages, attics, basements, sheds, container homes, and renovation projects.

How much area does one spray foam insulation can cover?

26 oz can covers around 20 sq.ft

Can I use spray foam insulation cans for walls, attics, and roofs?

Yes. Our spray foam insulation cans are suitable for walls, attics, roofs, crawl spaces, garages, and metal buildings.

What is the R-value of your spray foam insulation can?

Our closed-cell spray foam provides an R-value of approximately 5.66 per inch of thickness.

Is specialized equipment required for contractors to apply this foam?

To achieve optimal results, use a professional spray foam applicator gun, which ensures controlled flow, uniform expansion, and more efficient foam application on large insulation jobs.

Where Others Use Ixirpro Foam

Ducts

Boats

Attics

Basement

Doors

Window Slopes

Canals

Walls

Car Bodies

Caravans

Why Contractors Choose IxirPro Spray Foam

Evaluate how IxirPro professional spray foam insulation systems perform compared to standard insulation options commonly used in building projects.

IxirPro

Others

Thermal Efficiency

Install on Your Own Timeline

Contractor Scalability

No Unexpected Costs

Fast, Simple Setup